Labview An Input Parameter Is Invalid

Contents

This occurs when I use the various File I/O sub VI's that require file path as an input. Error message from server: %s. 1090 Specified object cannot be moved. 1091 The VI Server or client received an unrecognized message. 1094 Queue and notifier references of the same name must There are only two ways to tell somebody thanks: Kudos and Marked Solutions Unofficial Forum Rules and GuidelinesThe discussions from the Advanced User Track is not over. To correct this error, save to a folder instead of an LLB. 1497 Cannot unlock a library for edit when instances in running VIs exist. 1498 Library has errors. Source

Answered Your Question? 1 2 3 4 5 Document needs work? Thank you so much for taking time to looking into it. Verify the ability name does not contain spaces. 1469 Specified ability already exists. I put a probe on the name-ref where the error occurs and when there is an error the value is default 0. https://forums.ni.com/t5/LabVIEW/Error-1-Message-Input-Parameter-is-Invalid/td-p/223830

Labview An Input Parameter Is Invalid

There are lots of reasons this may be happening. To correct this error, wire the required input. 1398 The subVI cannot be inlined because there is a local variable in the block diagram. 1399 The subVI cannot be inlined because To correct this error, ensure that a drag and drop operation is in progress when you call this function and that the data type and drag data name match what is Use the following information as a reference: Error 1 occurred at EndUpdateResourceA.vi Possible reason(s): LabVIEW: An input parameter is invalid.

You need to actually wire a value to them. Untitled.png ‏135 KB 0 Kudos Message 1 of 9 (1,095 Views) Reply 0 Kudos Re: Error 1: Write to Text File GerdW Knight of NI ‎03-21-2011 11:24 AM Options Mark as You tried to insert a VI into a subpanel control, but the front panel or block diagram window you want to insert does not exist. 1308 The Property or Invoke Node This just happened to me again with the exact same message shb posted.

The Scan From String function was unable to scan its input because the data was not in the expected format. The distributor must include compiled code in the file for it to run in the LabVIEW Run-Time Engine. 1575 The function name for the %s node cannot be found in the IhavesetupsomehookstoseeiftheerrorhappensbeforeoraftertheVI. (TheVIwasopenedbythepre-buildhook.)Errorinisnoerror. The input string does not contain data in the expected format.

When doing the loop as shown in the snipped I got windows error 6 at the 2nd try. The specified property code is not valid for this refnum. −1967345150 Invalid privilege ID. This normally is a user data file. 116 Unflatten or byte stream read operation failed due to corrupt, unexpected, or truncated data. 117 Directory path supplied where a file path is Poor|Excellent Yes No Document Quality?

Labview Error 6

It certainly could be a race condition where you are trying to read a local variable of a file reference before you've set it. 1 Kudo Message 6 of 9 (1,052 The application attempted to write to the file while it was being played. Labview An Input Parameter Is Invalid If you do not have the right amount of data to align to a sector size, you must pad the data with filler data and delete the filler data before LabVIEW Labview Error Codes My Profile | RSS | Privacy | Legal | Contact NI © 2014 National Instruments Corporation.

All rights reserved. http://robertwindows.com/labview-error/labview-error-6.html Solution: This error can be caused if you have named your executable with an invalid file name character such as a carriage return or any of the following characters: \ / Then after the consumer loop is complete, kill the queue. Hence the error 1.The Booleans will never light up because you don't have anything wired to them.

Code resource already loaded. 1307 Subpanel control could not open the VI window. For example, if you have a VI with one vertical splitter bar, and the minimum size of the left pane is 50, wiring 10 to the Splitter Position property will return This error occurs when you try to use the Default Frame property with a Diagram Disable structure. have a peek here Best regards,GerdWCLAD, using 2009SP1 + LV2011SP1 + LV2014SP1 (+ LV2016 sometimes) on Win7+cRIOKudos are welcome 1 Kudo Message 2 of 9 (1,081 Views) Reply 1 Kudo Re: Error 1: Write to

but now i know more about the labview data flow" That's a contradiction (Adding even more "variables" has nothing to do with dataflow...) Best regards,GerdWCLAD, using 2009SP1 + LV2011SP1 + LV2014SP1 The palette view format must be Icons, Icons and Text, or Text. The frequency for a data point is then calculated as f0+N*df.

Raising this application's priority level could resolve this issue. 4803 The sound driver or card does not support the desired operation.

In your instance, I like to send an empty array. Recompiling the VI may fix this issue. 4800 Selected Device is Invalid The currently selected device index is invalid. Go to Solution. The control reference of the control does not belong to the VI that owns the Property or Invoke Node. 1311 The input for class name is not correct or is in

Contact ShadesOfGray for current posts and information. 0 Kudos Message 2 of 6 (1,017 Views) Reply 0 Kudos Re: Error 1 occured at get queue status crossrulz Knight of NI ‎06-06-2013 I hope this will help some noobs like me... I wasn't able to figure out the origin of the error and what causes it. Check This Out is FALSE and a queue or notifier with that name was not found, LabVIEW returns this error. 1102 The string wired to the xml string input is empty. 1103 The XML

The graph will accept the 2D array just fine. I hope this will help some noobs like me... This error occurs when you use an index value that is out of range to access a frame in a Case, Stacked Sequence, or Event structure. 1313 You cannot use this For example if the input is a path, the path might contain a character not allowed by the OS such as ?

More details will follow soon. I have already tried to save it and change VI's and save again, it does nothing, i have read here it was possible to change the string command of misc icon To set the state of the open front panel, use the Front Panel Window:State property. 1151 Invalid input for front panel state. 1156 Memory full error, possibly due to a data The error happens occasionaly and I can not figure out what causes the error.

The conversion will actually cause the Call Instrument.vi to fail. There are duplicated items in the array. 1304 The array index is outside of the array bounds. 1305 The required page cannot be found. 1306 Unable to load new code resource