Home > Labview Error > Labview Error 6

Labview Error 6

Contents

To resolve this error, give the file a path that does not already contain a LabVIEW file in any open application instance. 1358 The splitter bar cannot be moved to this NoteIf you attempt to close a project reference, LabVIEW may not remove the project in memory even if you close all references to that project because either the Project Explorer window Please Contact NI for all product and support inquiries. Another possible cause for this error is there might be a bad network connection. Source

Right-click the container border and select Replace or drag new subtype. 1096 The Open VI Reference function cannot prepare a non-reentrant VI for reentrant run. This error can occur when you write a frequency domain waveform to a file with Segment Headers set to One header only. To correct this error and inline the subVI, remove the implicit control reference. 1485 LabVIEW cannot inline the subVI into its calling VIs because the block diagram of the subVI contains This ensures that files are closed correctly. https://forums.ni.com/t5/LabVIEW/Error-1-Message-Input-Parameter-is-Invalid/td-p/223830

Labview Error 6

YourFeedback! On the otherhand, since you did mention that you are doing GPIB communication, if one of those VIs is throwing the error, the second error message would be more relevant. If you are using the Open/Create/Replace File function or Open/Create/Replace Datalog function, you can wire cancelled to the selector terminal of the case structure instead.

Refer to the help for the property or method to determine if it is allowed remotely. 1033 Bad run-time menu file version. 1034 Bad run-time menu file. 1035 Operation is invalid The default is to display a file dialog box and prompt you to select a file. I had checked up the wiring of my close data file item, but everything were OK, then i have thought about my loop. This widget could not be displayed.

Sync up changes before attempting this operation. 1500 If you obtain a user event reference in one application instance, you cannot use that user event reference in another application instance. Labview Error Codes The value for palette width must be 0 or greater. −4403 A palette item is invalid. If you want to read or write a data file to a Redundant Array of Independent Disks (RAID), consider opening the file without buffering to speed up data transfers. http://digital.ni.com/public.nsf/allkb/DF54DD9E94D46D2886257C4D006A419E Another application is currently using the device.

In the previous example, you do not need to close the front panel reference because the front panel reference closes when you close the VI reference. The application attempted to write to the file while it was being played. The return type must be Void, Numeric, or String. No reference could be returned.

Labview Error Codes

Paths to VIs and palette files (.mnu) must be valid. −4402 The palette view format is invalid. http://forums.ni.com/t5/LabVIEW/Error-1-is-to-open-file-vi-Openfile-occurred-Fehler-1-ist-bei/td-p/1751244 I recently had trouble with getting Error 1 from a Close File function. Labview Error 6 path is the corresponding path to refnum. Otherwise, LabVIEW may return an error when LabVIEW attempts to close the front panel reference.

Yes No Submit Den här webbplatsen använder cookies för att ge dig en bättre upplevelse. http://robertwindows.com/labview-error/labview-error-1445.html This widget could not be displayed. Try freeing up disk space or saving to a different disk or drive. 10 Duplicate path. 11 Too many files open. 12 Some system capacity necessary for operation is not enabled. On Linux or Mac OS X use chmod to set file permissions.

Only that instance can be reverted. 1468 Specified ability not supported by the library. Fix the errors before attempting this operation. 1499 Library has edits in another context. You can use the Close Reference function (linked below) to close a reference. have a peek here Poor|Excellent Yes No Document Quality?

Why does this occur? The device driver needed to execute the In Port and Out Port VIs is not present. It works.

To correct this error, wire the required input. 1398 The subVI cannot be inlined because there is a local variable in the block diagram. 1399 The subVI cannot be inlined because

But i got two problems : ----> first, when i want to stop my acquisition, when labview program close the file, it gives me a known error you guys know First of all i got a simply programto begin (cause it is too tricky for me ) This one open a path file where the measurements will be recorded, take measurement If you do not have the right amount of data to align to a sector size, you must pad the data with filler data and delete the filler data before LabVIEW If LabVIEW leaks a VI reference, your program may behave incorrectly if you expect LabVIEW to unload the VI and reset the state of the VI for the next call.

All rights reserved.|

If it is a path, this function opens the file specified by the path. Verify the path for each item in the items array. Check This Out If a Start Asynchronous Call function makes a call-and-forget VI call, that VI is a separate top-level VI.

I have already tried to save it and change VI's and save again, it does nothing, i have read here it was possible to change the string command of misc icon Why does this occur? error out contains error information. The requested entry could not be found. −120000 LabVIEW SignalExpress is required to open this ExpressVI.

This might have corrupted the LabVIEW memory. The palette type value has enumeration values of Controls or Functions. The specified access type is not valid. −1967345148 Invalid argument. Install LabVIEW SignalExpress or visit www.ni.com/labview/signalexpress to download an evaluation version. −40601 The deterministic communication engine failed to initialize hardware. −4850 Device driver not present or not supported.

Recompiling the VI may fix this issue. 4800 Selected Device is Invalid The currently selected device index is invalid. To disable buffering, wire a TRUE value to the disable buffering input. However, if you close the front panel reference, you must do so before closing the VI reference. To correct this error, ensure that a drag and drop operation is in progress when you call this function and that the data type and drag data name match what is