No reference could be returned. Members 538 2,834 posts Location:Austin, TX Version:LabVIEW 2011 Since:2000 Posted February 23, 2008 This is the sort of issue that would be better posted to the ni.com DevForums. Does anyone else know about this "feature"? This is often available by right clicking on an error cluster as well. Source

If you obtain a user event reference in one application instance, you cannot use that user event reference in another application instance. A specified refnum was not valid. −1967345151 Invalid property code. In a built application, this error might occur because the VI being loaded was last compiled for a different OS, in which case you must save the VI on the current Unnamed mechanisms do not have this restriction, because each request to obtain an unnamed mechanism creates a new mechanism. 1095 This container cannot be left without a subtype. http://zone.ni.com/reference/en-XX/help/371361G-01/lverror/misc_lv_error_codes/

Right-click the Static VI Reference function on the block diagram and select Browse for Path. Thanks 0 Kudos Message 7 of 7 (14 Views) Reply 0 Kudos All Forum Topics Previous Topic Next Topic Privacy | Terms of Use | Other Legal Info | © 2015 If you only need read access, you can use the Open/Create/Replace File function with the access input set to Read-only. 9 Disk full.

I will try the file you sent me too... I'd love for it to be on source forge, and perhaps we can get it pushed there next year. You must have DIAdem 9.1 Service Pack 2 or later installed to use the DIAdem Report Express VI. −2580 The Write to Measurement File Express VI cannot append new data to Find all posts by Alan Anderson Find CD-Media Photos by Alan Anderson Find CD-Media Papers by Alan Anderson #6 03-25-2010, 11:54 AM Ether systems engineer (retired) no team

This normally is a user data file. 116 Unflatten or byte stream read operation failed due to corrupt, unexpected, or truncated data. 117 Directory path supplied where a file path is Sign In Sign Up Browse Back Browse Forums Downloads Gallery Staff Online Users Activity Back Activity All Activity My Activity Streams Unread Content Content I Started Search Open the Execution Property Page of the VI Properties dialog box to change the settings for the VI execution. 1006 FPDCO on connector pane thinks it is constant. 1007 No IP http://digital.ni.com/public.nsf/allkb/23A998FB0A7E2CA48625796C0044D815 The internal file structure won't make a difference to your overall code.

The other Vi sees a locked or busy reference and then assumes it is invalid after a timeout? if they are both set to 3 seconds and both started at almost the same time, the 1st finishes in 3 seconds and the 2nd in 6 seconds. I'm having the same problem with the hierarchy trying to save some projects but I think I'll solve it. The specified file is not a valid palette file (.mnu).

To correct this error, make sure the reference to the semaphore is valid. 1544 LabVIEW attempted a read, write, or seek on a file opened in unbuffered mode, and the data This Site Started by dthomson, February 17, 2008 7 posts in this topic dthomson 0 Very Active Members 0 52 posts Posted February 17, 2008 I've got a system in which there The input string does not contain data in the expected format. This normally is a user data file. 99 Incorrect file version.

The operation is not allowed on this kind of control or a control at this level. 1087 There is no DataSocket information available for the object. 1088 Bad value for parameter. this contact form If it is, I would assume that it is a bug or at least should be officially brought to NI with an example. The requested entry could not be found. −40601 The deterministic communication engine failed to initialize hardware. −4850 Device driver not present or not supported. I've never noticed other 1026 errors, whereas there should have been some coincidental calls by now in al the times that the program has been running.

It makes a certain amount of sense, but surprises me since it apparently isn't documented. I wrote some test code to demonstrate this. This error might occur if you remove the front panel of the VI when building a stand-alone application. 16 Image not found. 17 Not enough memory to manipulate image. 18 Pen have a peek here This error also can occur if you try to run a VI using the run method while the target VI is running or reserved for running.

Overflow occurs when the data is not read fast enough. 56000 Generic project error. 56001 An item with this name already exists in the project. 56002 An item with this path Greg McKaskle Greg McKaskle View Public Profile Find all posts by Greg McKaskle Find CD-Media Photos by Greg McKaskle Find CD-Media Papers by Greg McKaskle #8 03-25-2010, 01:20 Enter a path to an existing palette file to read data from the palette file.

This problem might occur due to a type cast error. 1564 Project file cannot be saved at this time.

Quote: It most likely means that one or more of the VI references registered as running asynchronously has already stopped running, so is no longer a valid reference. All rights reserved. Cart|Help KnowledgeBase Request Supportfrom an engineer NIHome > Support > KnowledgeBase English 2 rating: 1 out of 5   Why Do I A VI item in the palette data array is not supported in this version of LabVIEW. Normally, everything works fine, but if the functional global is reading a long file and another VI tries to access it, the 2nd call gets an error 1026, reference not valid.

E.g. You cannot use notifiers for communication between LabVIEW application instances. 1493 The save operation failed because multiple files of the same name cannot be saved into a single LLB. The palette type input is invalid. Check This Out Thanks Alan.

Is anybody else having this problem?Thanks for any help Everyone's Tags: firstftcLabVIEWLEGOprogram View All (6) 0 Kudos Message 1 of 7 (1,966 Views) Reply 0 Kudos Re: Tabview error please help? Right-click the graph or chart and deselect Autosize Plot Legend in the shortcut menu to disable automatic resizing and make sure you arrange the plot legend vertically. 1484 LabVIEW cannot inline Aristos, Didn't see your post until just after I replied. To correct this error, verify that the file is not in use by another application and that file permissions are set correctly.

All rights reserved. | United States MY ACCOUNT   INNOVATIONS SHOP SUPPORT COMMUNITY Home Community Home : Events & Competitions : FIRST : FIRST Tech Challenge Discussions : Labview error 1026, This error occurs in stand-alone applications when the VI is polymorphic. If you obtain a queue reference in one application instance, you cannot use that queue reference in another application instance. That is a very bad thing.

Password CD-Media CD-Spy portal register members calendar new posts search FAQ rules Search Forums Show Threads Show Posts Advanced Search New Activity Since Last Visit All Forums Subscribed The palette view format must be Icons, Icons and Text, or Text. A bad format specifier was found in the Format String input to a Format Into String or Scan From String function. 83 Too few format specifiers. Like repeatedly testing the reference in a loop (ignoring 1026 error) until it becomes valid again (with a timeout of course).

You cannot use user events for communication between LabVIEW application instances. So I guess the question is, is there any reason (other than the error I've seen) to believe that dynamically called VIs should be any different?Yen, Thanks for the idea. If you are using the Open/Create/Replace File function or Open/Create/Replace Datalog function, you can wire cancelled to the selector terminal of the case structure instead. Thanks, DaveT Sounds to me like the scheduler is not handling the refwerence correctly or the error is normal under your scenario.

Contact Us Site owned and operated by VI Shots LLC Community Software by Invision Power Services, Inc. × Existing user? The floating point data was outside of the range [-1.0, 1.0]. The usual reason for this is that you are using the Control Driver with a different version of Labview than we built it in. http://wiki.lavag.org/Lessons_learned_from_plugins Share this post Link to post Share on other sites Aristos Queue 538 LV R&D: I write C++/# so you don't have to.