Home > Labview Error > Labview Error Code 91

Labview Error Code 91

You can use the Obtain Queue or Obtain Notifier function to look up a queue or notifier by name. So, beware of using the Control Value.Get with strictly typedef'd datatypes. write INI clusterand read INI cluster. no, it is unlikely to befixed. Source

Thishappens automatically if the wire type is LVClass and not variant, evenwhen the two AppInstances are on the same computer. Making sure 2009 was open when I dbl clicked made sure I was using 2009, and it worked ok without moding. My PC is now running much faster and is far more reliable. Change the execution mode of the referenced VI to reentrant for this operation. 1301 The dimension of the array passed in does not match the expected dimension for the operation. 1303 useful reference

Future requests to obtain a reference to the same mechanism (using the mechanism's name) must wire the same data type as the original call. LabVIEW cannot return a reference to the semaphore. The "Easy Parse XML.vi" do not report any error.

It has nothing to do with 'Strict Type Defs' afterall. A waveform must have 0 or 1 dimensions. 1177 Invalid data type for Call Library Function Node parameter. All rights reserved.| Jump to content LabVIEW Bugs Existing user? The specified property code is not valid for this refnum. −1967345150 Invalid privilege ID.

event. Solved! Contact the distributor of the file. http://zone.ni.com/reference/en-XX/help/371361J-01/lverror/misc_lv_error_codes/ Solved!

GerdWs Signatur. 03.11.2011, 10:44 Beitrag #8 Cillinar LVF-Grünschnabel Beiträge: 17 Registriert seit: Aug 2011 2010 2011 EN Oesterreich RE: Fehler 91 bei der Arbeit mit Variant... If it is reentrant, use the Open VI Reference function with the options input set to 0x08 to prepare the VI for reentrant run or use the Open VI Reference function See attachment "Ok.jpg" for the test code. Thanks for the info.” Your Name Your Email Comment Error Code 91 Labview There are thousands of problems that error code 91 labview your personal computer could have, windows 7

Then create a constant from the indicator and use this constant as the new type for the variant.) OR 2) Use a Flatten Variant to String and then an Unflatten from Fix the errors before attempting this operation. 1499 Library has edits in another context. To run a VI using a static VI reference, use an Invoke Node to call the Run VI method. Wenn das Programm in der Entwicklungsumgebung läuft, ist alles ok.

I can switch backwards and forwards between it working and not working, so I'm not sure what you mean by "adding back the strict typedef setting has no effect" Hmmm. 2 http://robertwindows.com/labview-error/labview-error-code-32.html You can use this property only with the Conditional Disable structure. 1377 A Diagram Disable Structure cannot have conditions. The only correct way to shuffle object data from AppInstance 1 toAppInstance 2 is to flatten it to string and unflatten it from string.This happens automatically when the two AppInstances are I guess no one has done so because it is so obvious to many, but it remains an undocumented behavior none the less.

This error can occur if you use a property or method that is not supported in the LabVIEW Run-Time Engine. 1044 VI is locked. 1045 Null Refnum passed to Close Reference. It must be loaded and saved in the current version of LabVIEW. 1453 You may only set the vertical arrangement on a label, caption or free label. 1454 LabVIEW classes cannot Register a new account Sign in Already have an account? have a peek here It seems that many scripting functions, editor extensions, etc, grab data across the boundaries.

After scanning my PC using RegCure, I can confirm that Error Code 91 Labview did not return. On Windows, navigate to the file, right-click the file, select Properties, and set the Read-only option in the dialog box. This error might occur if the create if not found input of the Obtain Semaphore Reference VI is FALSE and LabVIEW cannot find a semaphore with the name you specify. 1535

I think we had to copy the code into new vi to replace the problem vi.

The palette type value has enumeration values of Controls or Functions. Themen Verfasser Antworten Views Letzter Beitrag Variant-Attributsliste Hasenfuss 2 395 27.06.2016 15:10 Letzter Beitrag: Freddy Variant Attribute initialisieren NoWay 6 1.134 27.10.2015 08:56 Letzter Beitrag: IchSelbst Variant Datentyp See attachment "Ok.jpg" for the test code.The cluster element inside the array needs to be named 'Parameter' as well, so right click on the cluster border and select 'Visible->label' Ton Edited The palette type input is invalid.

To correct this error, ensure that a drag and drop operation is in progress when you call this function and that the data type and drag data name match what is Oder? Wait until the VI is not being modified to get the image of a panel or diagram. 1001 The VI front panel is not open. Check This Out The code posted is useful for my use case and really that what matters.   Thanks for your comments!

All I can do is show you this. That's wonderful reports as it ensures that error code 91 labview chances are great that error code 91 labview your dilemma is well reported and may most likely be solved by The control reference of the control does not belong to the VI that owns the Property or Invoke Node. 1311 The input for class name is not correct or is in Code resource already loaded. 1307 Subpanel control could not open the VI window.

The parser don't care about that Label.