Labview Error Codes 2011

To resolve this error, give the file a path that does not already contain a LabVIEW file in any open application instance. 1358 The splitter bar cannot be moved to this A VI item in the palette data array is not supported in this version of LabVIEW. The right rank of the filter must meet: right rank < size. −20031 The filter cannot be designed with the specified input values. −20030 The leakage coefficient, leak, and step-size parameter, You also can contact National Instruments technical support for assistance with undefined error codes. Source

Try to connect to the front panel again, or request that the server administrator modify the front panel so it uses less memory. 1349 Client does not have access to specified The sound driver or card cannot accommodate the specified configuration. Refer to the KnowledgeBase for more information about correcting errors in LabVIEW. A filename is no longer sufficient because the full name of a VI now includes any owning libraries.

More data might be available. 1073676300 VISA received more event information of the specified type than the configured queue size could hold. 1073676407 The specified configuration either does not exist or This error can occur if you use a VI that is not supported in the LabVIEW Run-Time Engine. −4404 The value for palette width is invalid. For example, hexadecimal notation is not a valid format for floating point numbers. 1434 The precision is greater than the maximum allowed value for this format. 1436 Numeric precision cannot be The device driver needed to execute the In Port and Out Port VIs is not present.

Right-click the error in input and select Create»Constant from the shortcut menu. This error can occur if you attempt to edit a VI that is running or reserved for running. YourFeedback! Use only 0, 1, L, H, X, Z, V, or T. −1813 Too many signals to convert into the specified data type. −1812 Specified start position or duration is out of

Alignment of two waveforms is possible only if the samples share the same dt and are in-phase, that is the difference between their t0s is a integer multiple of dt. −20332 All rights reserved.| Cart|Help You are here:NI Home > Support > Manuals > LabVIEW 2011 Help Error Codes and Messages »Table of Contents LabVIEW 2011 Help Edition Date: June Add Comments 1 2 3 4 5 My Profile|Privacy|Legal|Contact NI© National Instruments Corporation. http://zone.ni.com/reference/en-XX/help/371361H-01/lvhowto/creating_user_defined_erro/ If you obtain a user event reference in one application instance, you cannot use that user event reference in another application instance.

This error might occur if you remove the front panel of the VI when building a stand-alone application. 16 Image not found. 17 Not enough memory to manipulate image. 18 Pen This description is the same description that appears in this help file. If you do not have the right amount of data to align to a sector size, you must pad the data with filler data and delete the filler data before LabVIEW Use the Window Appearance page to configure if the front panel is shown when the VI is run or loaded.

Another application is currently using the device. http://zone.ni.com/reference/en-XX/help/371361H-01/lverror/lverror_intro/ You must load an instance of the polymorphic VI instead of the polymorphic VI itself. 1125 File version is later than the current LabVIEW version. 1126 VI version is too early Legacy or Third-Party Drivers If you are using a driver that was released before LabVIEW 6.1, the driver installed a version of error.llb that contains all the driver error codes. A memory or network problem occurred.

For example, enter 5008. this contact form A VI is reserved for running when you open a reference to the VI by wiring a type specifier VI Refnum to the Open VI Reference function, or when you have Answered Your Question? To correct this error, load an instance of the polymorphic VI rather than the polymorphic VI itself. 1554 The current LabVIEW target cannot load control VIs. 1556 The reference is invalid.

When LabVIEW tries to move the splitter bar to the specified position, at least one pane shrinks smaller than its set minimum size. The operation is not allowed on this kind of control or a control at this level. 1087 There is no DataSocket information available for the object. 1088 Bad value for parameter. NoteAs an alternative to steps 6 through 8, you can wire a numeric constant with a value of 5008 to the Error Cluster From Error Code VI. http://robertwindows.com/labview-error/labview-error-codes-1097.html Answered Your Question?

Then wire the error out output of the Error Cluster From Error Code VI to the error in input of the General Error Handler VI. You must pass either 1 string or 6 strings. 1524 The target version for save is not formatted correctly. You can use the General Error Handler or Simple Error Handler VIs to obtain a description of these error codes.

For example, if you have a VI with one vertical splitter bar, and the minimum size of the left pane is 50, wiring 10 to the Splitter Position property will return

There is a size mismatch between the data in the reference and the data wired to the Data Value Reference Write Element border node. 1586 Compiled code is out of date. Poor|Excellent Yes No Document Quality? If this error occurs when specifying a machine name, make sure the machine name is valid. A specified refnum was not valid. −1967345151 Invalid property code.

Do not invoke any other handlers on this session for this event. 1073676441 Operation completed successfully, and this session has nested shared locks. 1073676442 Operation completed successfully, and this session has To correct this error, you must obtain a valid license for the VI and its containing library. 1389 You are attempting to save or copy a VI that is either in This is usually due to previous events not having been closed. −1073807313 You must be enabled for events of the specified type in order to receive them. −1073807312 User abort occurred Check This Out An example of the correct format is: B62C4E8D-62CC-404b-BBBF-BF3E3BBB1374. 1101 Insufficient privileges to read, write, or create an item in the DataSocket Server.

This is usually due to a required driver not being installed on the system. −1073807201 The interface cannot generate an interrupt on the requested level or with the requested statusID value. Make sure you include the front panel of the VI when building a stand-alone application. 1014 Linker error. 1015 Printer is not responding. Ensure that you specify the URL of a remote endpoint with the reader url terminal of the Create Network Stream Writer Endpoint function or the writer url terminal of the Create The error code tables are arranged in ascending order, from negative to positive values.