Home > Labview Error > Labview Error Wire Connected To An Undirected Tunnel

Labview Error Wire Connected To An Undirected Tunnel

With the sequences, you can right click on the border and select options in the menu to add "frames" which provide another piece of block diagram to add code.There are other For example in the state machine - the error cluster wires should pass data from previous stacked sequence CASE 0 to CASE 1. Reason: Added picture AGPapa View Public Profile Find all posts by AGPapa Find CD-Media Photos by AGPapa Find CD-Media Papers by AGPapa #3 01-21-2014, 10:55 PM Alan Anderson Go to your block diagram and find that control. (Ifyou double click it from the front panel it will take you to the block diagram with the control highlighted) 9. Source

Replacing everything with the DVR as illustrated in the attached pictures.   Modified code:     Original code:     This class is used to store and manage message routes for With both versions of the sequence, there are multiple block diagram subsets represented, but without any dataflow order enforced, the first piece will execute to completion before going to the second The block diagram in the structure executes while FALSE is received by the stop icon and will stop when it receives TRUE. Contact us about this article Hi,   Is there any further optimizations that can be done to my program.    If I can make it faster it will be great.  

Using the Agilent's own  software the measures are fine, however using LabVIEW 8.6 the measures from two different temperatures (boiling water and air) are the same. I find it strange that only the timeout event has this problem and none of the other events have this problem! Otherwise I have to bundle everything and pass them onto outside of the event structure and thereafter distribute to each indicator, which is more complicate.

The Chief Delphi Forums are sponsored by Innovation First International, Inc. -- English (12 hour) -- English (24 hour) Contact Us - Chief Delphi - Rules - Archive - Top Powered Attached Thumbnails __________________ Team 2590 Student [2011-2014] Team 5684 Mentor [2015] Team 5895 Mentor [2016-] Last edited by AGPapa : 01-21-2014 at 06:27 PM. So, labview, at present,notonly controls thestepper motorthroughthe frequencysets,butalso simulatesthe output(in the specific, theresponse tothetorsionof the cartilage,simulatedwitha low pass filterofthe second order).All thiswas doneby my colleaguemore experienced than me, whotodaypassed methe finished This is what the front panel of your begin.vi should look like.

For example, no one has provided a description for the code, or you might have wired a number that is not an error code to the error code input. Anyway, all that was done was to to replace a dequeue/enqueue with a DVR reference. Hence, LabVIEW is not even "noticing" the voltage difference due to different temperatueres.I have configured inside agilent's temperature vi, (Transducer type RTD, RTD type 91) but the results are always the morefromWikipedia Servo control Servo control from a radio control receiver to the servos is done by sending each servo a PWM signal, a series of repeating pulses of variable width.

Your blog code helps a lot to beginners to learn programming from basic to advance level. Topic Options. Any idea? Regards :)  

0 0 06/14/13--11:51: Sampling rate X6341 Contact us about this article I am tying to collect samples at the highest rate possible in order to determine the

You find the answer there :-) 0 Kudos Message 8 of 14 (1,037 Views) Reply 0 Kudos Re: passing error wire - connected to an undirected tunnel abikutn Active Participant ‎06-15-2013 I found this site using [url=http://google.com]google.com[/url] And i want to thank you for your work. Hold down the CTRL key and select drag and drop the "Case Selector" control which will make a copy of it. Robust control methods are designed to function properly so long as uncertain parameters or disturbances are within some set.

I have another question about this code also in the timeout event: I have 4 references to 4 multicolumn listboxes feeding into the init listboxes subVI and one of these has http://robertwindows.com/labview-error/labview-error-code-91.html Sign In Sign In Remember me Not recommended on shared computers Sign in anonymously Sign In Forgot your password? One way is to convert those 1-N cases to another state machine and reuse it under the main state machine (for example the one I showed). If the specified value is found in the array, the vi should indicate that by turning on the LED and by indicating the corresponding index of the array    thank for

An comments are welcome. Remove any broken wires in your VI by selecting Edit»Remove Broken Wires or by pressing If you have tried both of the previous steps and are still seeing this error, You can wire any type of data into the left '?' terminal and possible values appear at the top center. have a peek here This is the steering actuator of a large robot vehicle. ]] A servomechanism, sometimes shortened to servo, is an automatic device that uses error-sensing negative feedback to correct the performance of

Poor|Excellent Yes No Document Quality? morefromWikipedia Servomechanism The grey/green cylinder is the brush-type DC motor. The Imaging Source USB 3.0 monochrome camera with trigger : DMK 23UM021OPERATING SYSTEM - [ MS windows 7 Home Premium 64-bit SP-1 ]CPU - [Intel Core i7-2600 CPU @ 3.40Ghz ]MEMORY

morefromWikipedia Robust control Robust control is a branch of control theory that explicitly deals with uncertainty in its approach to controller design.

Feel free to investigate those independently because you probably know enough about LabView at this point to learn about those on your own. When the source of the wire is inside the structure, the tunnel is an output. Undefined errors might occur for a number of reasons. I would love to hear any ideas on this problem.

The latest posting will be displayed on the main page, but please navigate the lessons as you would an online course or a book by using the Table of Contents below. Programming is very interesting and creative thing if you do it with love. Another window is opened up and where the drop down labeled 'Control' (next to the little spanner wrench) change itto 'Type Def'. 5.Left click "Case selector" control and select properties. 6. http://robertwindows.com/labview-error/labview-error-6.html I want to acquire a signal from a sensor and manipulate the data and the send it to the output of the actuator.   However when I was building my code with

If you right click on the stacked frame and select replace with flat sequence you will see where the logic goes wrong. Name this "case selector" or whatever you like. 3. Performance was good with the SEQ but it did have the above mentioned bug. Silly to justify a sequence structure in this case.

The time now is 06:37 PM. Why is that? Active Participant … NI LabVIEW software contains powerful debugging tools to help you identify problem areas in your code so you can make the appropriate changes…. Attached Thumbnails DarthMaulCIS View Public Profile Find all posts by DarthMaulCIS Find CD-Media Photos by DarthMaulCIS Find CD-Media Papers by DarthMaulCIS #2 01-21-2014, 06:14 PM AGPapa Registered

Thank you for pointing that out. The results should  be displayed in an array. For these third-party errors, you might be able to obtain a description of the error by searching the Web for the error code (-2147023170) or for its hexadecimal representation (0x800706BE). The Imaging Source USB 3.0 monochrome camera with trigger : DMK 23UM021OPERATING SYSTEM - [ MS windows 7 Home Premium 64-bit SP-1 ]CPU - [Intel Core i7-2600 CPU @ 3.40Ghz ]MEMORY

The Imaging Source USB 3.0 monochrome camera with trigger : DMK 23UM021OPERATING SYSTEM - [ MS windows 7 Home Premium 64-bit SP-1 ]CPU - [Intel Core i7-2600 CPU @ 3.40Ghz ]MEMORY After the modification the messaging system seems to loose routes as well as the performance of the system dropped significantly. NI PXI-7951R & NI 57612. All rights reserved. | United States MY ACCOUNT   INNOVATIONS SHOP SUPPORT COMMUNITY Home Community Home : Discussion Forums : Most Active Software Boards : LabVIEW : passing error wire -

Related Links: LabVIEW 2013 Help: Wire connected to an undirected tunnel KnowledgeBase36QD14V3:Why Do I Receive a "Memory is Full, VI Stopped at Loop Tunnel 0xXXXX" Error? All rights reserved. Please Contact NI for all product and support inquiries. Abhilash S NairResearch Assistant @ Photonic Devices and Systems lab[ LabView professional Development System - Version 11.0 - 32-bit ]LabView Gear:1.

The lessons are geared towards LabView 8.5.