Home > Labview Error > Labview Generic File I O Error Could Not Be Loaded

Labview Generic File I O Error Could Not Be Loaded

Contents

The file is just a few dozens to a few hundred KB. But i do not care as long as you provide me with information. I think you should reconsider this. Share this post Link to post Share on other sites Kyoma Hooin 0 LAVA groupie Members 0 5 posts Version:LabVIEW 7.1 Since:2014 Posted July 17, 2015 (edited) This is read Source

Dennis_Knutson Knight of NI ‎08-08-2011 09:50 PM Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print Email to a Friend Report to a Moderator The error has nothing Without the real source it becomes difficult to help you. So I really do not know how it functions but I know that it works because we ran it through different programs before and it worked perfectly. Is that part of a plasma rifle or a quantum defibrillator?

Labview Generic File I O Error Could Not Be Loaded

Share this post Link to post Share on other sites chris754 8 Very Active Members 8 63 posts Version:LabVIEW 2013 Since:2006 Posted July 14, 2015 Sorry, For the late response See KnowlegeBase 3DN7C7CC: Error 1 or Error 6 Occurred During File I/O - Input Parameter is Invalid for more information. Once this has been done, the source path that is input to Copy.vi only needs to contain the computer name and the shared folder name (i.e.

amitin Member ‎08-17-2011 06:25 AM Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print Email to a Friend Report to a Moderator another thing,I have been able to So I really do not know how it functions but I know that it works because we ran it through different programs before and it worked perfectly. The Windows file naming conventions are not met. Labview Error Codes In this case it is not even software I wrote so how would we have been able to even guess from the first two posts of the OP that GPIB might

A maximum of 8 characters before the dot, and a maximum of 3 after the dot. Labview Generic File I/o Error. ========================= Ni-488 I/o Operation Aborted If using LabVIEW 6.1 or earlier, the file name must conform to the 8.3 naming convention. If the folder you are writing to gets too large, Error 6 can be triggered. The path has been incorrectly specified, which is most often caused by improper formatting of the path.

You are writing to a folder on the network that is not shared or the network communication has been interrupted. amitin Member ‎08-07-2011 04:14 AM Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print Email to a Friend Report to a Moderator thank you for the answer. Labview say: "Generic error of function of E/S on files". 0 Kudos Message 7 of 14 (2,376 Views) Reply 0 Kudos Re: error 6 jajassa Member ‎05-24-2006 04:17 AM Options Mark I din't see the problem.

Labview Generic File I/o Error. ========================= Ni-488 I/o Operation Aborted

thanks again, your answer helped me Cheers Antoine Share this post Link to post Share on other sites Create an account or sign in to comment You need to be a https://forums.ni.com/t5/LabVIEW/error-6/td-p/368570 If deleting files or folders, ensure that the application has permissions to modify the files or folders. Labview Generic File I O Error Could Not Be Loaded Please tell us why. Labview Error 6 Occurred At Delete So I copied the exact same function to my program and put it in a while loop and ran the program which gave me an error and pointed to the code

Our ion gauge displays the pressure that is connected to the computer through GPIB connection.   My Professor created a code that was made to read the pressure that is displayed this contact form In Linux, you must open a pipe in Read Mode before trying to open it it Write Mode. Then, you can probe along the error chain to see exactly where the error occurs (as opposed to just 'At Delete' or 'At List'). suppression_mod2.vi ‏114 KB 0 Kudos Message 9 of 14 (2,348 Views) Reply 0 Kudos Re: error 6 jajassa Member ‎05-24-2006 09:46 AM Options Mark as New Bookmark Subscribe Subscribe to RSS Generic File I/o Error Labview

LabVIEW Register for the community · Log in · Help CommunityCategoryBoardDocumentsUsers turn on suggestions Auto-suggest helps you quickly narrow down your search My Profile | RSS | Privacy | Legal | Contact NI © 2014 National Instruments Corporation. Our ion gauge displays the pressure that is connected to the computer through GPIB connection.   My Professor created a code that was made to read the pressure that is displayed have a peek here Attachments: Report Date: 03/04/2012 Last Updated: 01/05/2016 Document ID: 5V3KFEYJ Your Feedback!

This can be solved by creating a new folder to write to. Poor|Excellent Yes No Document Quality? Some information about the measuring system:There are three NI 9172 chassis which include the following modules:Chassis 1: 4x NI 9205; 1x NI9403; 1x NI9481Chassis 2: 8x NI 9217Chassis 3: 4x NI

We still only can guess that it is probably the GPIB function causing that error. 1 person likes this Share this post Link to post Share on other sites Jordan Kuehn

Primary Software: Primary Software Version: 7.1 Primary Software Fixed Version: N/A Secondary Software: LabVIEW Development Systems>>LabVIEW Base Package Problem: I am trying to use the Copy.vi from the File I/O subpalette Cart|Help KnowledgeBase Request Supportfrom an engineer NIHome > Support > KnowledgeBase English 16 rating: 1.5 out of 5   Archived: Why am I Getting Error Please post the code Share this post Link to post Share on other sites Kyoma Hooin 0 LAVA groupie Members 0 5 posts Version:LabVIEW 7.1 Since:2014 Posted July 9, 2015 OK, they call them snippets, but they are screenshots and they say it is code, right?   edited to add emoticons for Rolf Edited July 10, 2015 by ShaunR 1 person

You know more about your software than anyone here does, so you need to tell us as much as possible about it in order to allow us to help you!   I would say path of the file, excuz me. This works fine during some days, but it occured now twice (always after 2-3 weeks), that error 6 appeared and it poped up a message, that something with "Write Spreadsheet String.vi" Check This Out Since the file is being saved relative to the location of the VI, if the path is on a network drive, you might be running into network issues. "Filename" is an

My Profile | RSS | Privacy | Legal | Contact NI © 2014 National Instruments Corporation. Che_T. This causes no problems. You dould do the same thing with the error out to enable you to match the error generated with the file name.

Attached is a VI that demonstrates a solution that utilizes the Search and Replace Pattern.vi.This error could also occur if you specify a file name without a drive path inside a Answered Your Question? 1 2 3 4 5 Document needs work? Solution: This error code is associated with several problems that can occur when specifying the source path that is input to the File I/O VI's. But i do not care as long as you provide me with information.   They are asking you to post the source (the actual VIs) not a text file or an

And what you mean with "the way of the file is without error it exists" (perhaps adding the French version would help)?Paolo Paolo-------------------LV 7.0, 7.1, 8.0.1, 2011 0 Kudos Message 2 Thus, setting up a folder to be shared will essential put up a flag for which the File I/O VI's know to look. As the gas ions is being collected the flow of the ions creates a current.